(UN2000B) Hospital Medical ICU Personal Care Touchscreen Patient Monitor with Bluetooth
Model:UN2000B
Waveform:ECG and SPO2 waveforms
Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data |
Build-in rechargeable Li-battery, up to 15Â hours running time, support AC and DC power |
Adjustable audible and visual alarms, and sensor off alarm |
Long time monitoring and sleeping monitoring |
Easy to carry, suitable for ambulance center, has the stand for fixing |
ETCO2, FiCO2 and RR are optional |
Priors
Â
Storage and review data up to 3888groups via Trend Graph and Trend List |
USB and Bluetooth data upload |
Big font screen interface is easy to observe |
Back light can be adjusted |
Free advanced software are all standard on free |
Optional Bluetooth printer to print the waveform and data out |
Parameters
ECG
Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm
SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device.Â
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC
EtCO2(Optional)
Measuring Range: Â 0~150mmHg
Resolution:Â 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm
Printer (optional)
Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V. Â
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH
Storage Operation/relative humidity:-20~60ºC/10~90%RH
Payment
Shipping
Â
Model:UN2000B
Waveform:ECG and SPO2 waveforms
Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data |
Build-in rechargeable Li-battery, up to 15Â hours running time, support AC and DC power |
Adjustable audible and visual alarms, and sensor off alarm |
Long time monitoring and sleeping monitoring |
Easy to carry, suitable for ambulance center, has the stand for fixing |
ETCO2, FiCO2 and RR are optional |
Priors
Â
Storage and review data up to 3888groups via Trend Graph and Trend List |
USB and Bluetooth data upload |
Big font screen interface is easy to observe |
Back light can be adjusted |
Free advanced software are all standard on free |
Optional Bluetooth printer to print the waveform and data out |
Parameters
ECG
Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm
SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device.Â
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC
EtCO2(Optional)
Measuring Range: Â 0~150mmHg
Resolution:Â 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm
Printer (optional)
Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V. Â
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH
Storage Operation/relative humidity:-20~60ºC/10~90%RH
Payment
Shipping
Â
Carrot is a kind of vegetable which is rich in nutrition and easy to process. The raw materials are bright red, the section yellow core is small, and the luster is not damaged. Processing should be selected one by one, cut off the non-edible parts, wash 2 to 3 times, according to the requirements of cutting into various shapes, such as block, sheet, stripe, dice, round pattern, stripe pattern, etc. the remaining material is generally processed into dice. The products used for export should be removed according to the requirements of merchants, and the peeling machine can be used for mass production. The processed products are blanched for 1-3 minutes in the hot water of 100 C in the basket. The blanching degree should be strictly controlled. If the blanching is excessive, the products will become soft and discolored, which will affect the quality of the products. After blanching, chill to below 10 C, drain on the vibrating drainer, freeze in the quick freezing device for 10 minutes, and pack quantitatively and refrigerate. Customers who need to freeze Diced Carrots can contact us at any time.
Frozen Diced Carrots,Diced Carrots,New Crop Carrot,Frozen Carrot Cube
LETING JINTIAN FRUIT AND VEGETABEL CO., LTD. , http://www.chinafrozenvegetable.com